-40%

Stanford Research Systems SR245 Computer Interface Module

$ 263.99

Availability: 100 in stock
  • Brand: Stanford Research Systems
  • Condition: Used
  • MPN: SR245
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Return shipping will be paid by: Buyer

    Description

    Stanford Research System SR245 Computer Interface Module. Item came from a working environment. Additional Information from SRS:
    The SR245 Computer Interface module is a powerful tool for data acquisition. It provides both an analog and a digital interface between your computer and your experiment.
    Eight analog I/O ports
    8-bit digital I/O port
    Two TTL I/O ports
    RS-232 and GPIB interfaces
    3500 point sample memory
    Simple command structure
    SR245 Specifications
    Analog Ports
    Configuration
    Any number of the eight ports may be designated under program control as input ports, the rest default to output ports.
    Inputs
    1 MΩ impedance, ±10.24 VDC range, protected to 40 VDC. 13-bit resolution (2.5 mV). 0.5 % accuracy. Input offset <2.5 mV. Maximum A/D rate is 2 kHz.
    Outputs
    <1 Ω impedance. Short circuit current limit is 20 mA. 13-bit resolution (2.5 mV), 0.5 % accuracy. Output offset <2.5 mV
    Digital Ports
    Type
    Two front-panel I/O TTL bits, one 8-bit digital input port, one 8-bit latched digital output port
    Front-panel inputs
    Input impedances >100 kΩ. Minimum pulse width is 200 ns. Maximum count rate is 4 MHz. Logic one >3 VDC, logic zero <0.7 VDC. Inputs protected to ±10 VDC
    Front-panel outputs
    Can drive 50 Ω loads to TTL levels
    General
    Interfaces
    IEEE-488 (GPIB) and RS-232 (110 baud to 19.2 kbaud)
    Power
    +24 V/60 mA, 24 V/60 mA, +12 V/20 mA, approx. 8 watts
    Mechanical
    Single-width standard NIM module
    Input/Output Commands
    I n=0 to 8
    Designates the first n analog ports as inputs, the remainder become outputs.
    ? n=1 to 8
    Returns the value of the designated analog port.
    ?B n=1,2
    Returns the value (0 or 1) of the designated digital port.
    ?D
    Returns the value of the 8-bit digital input port.
    ?S
    Returns the value of the status byte, and clears the status byte.
    C
    Configures B2 as an input and resets the B2 counter.
    ?C
    Returns number of pulses occurring at B2 since the previous ?C.
    S=
    Sets the analog port n (which must be designated as an output) to the value x (x=-10.237 to +10.237 V). n=1 to 8
    SB=
    Designates digital bit n as output and sets its value to m (n=1, 2 and m=0, 1)
    SB=I
    Designates the selected bit as an input (n=1, 2)
    SD=
    Sets the 8-bit digital output port to the value n (n=0 to 255)
    SM=
    Sets the GPIB SRQ mask to the value n (n=0 to 255)
    Trigger Commands
    MS
    Sets the synchronous mode. Responses to ? commands are returned after next trigger.
    MA
    Sets the asynchronous mode (default). Responses to ? commands are returned after command is received.
    T
    Designates every n
    th
    pulse at B1 as a trigger (n=1 to 32,767)
    DT
    Masks the trigger input so that no triggers are recognized
    ET
    Unmasks the trigger input
    PB
    Outputs a 10 µs TTL pulse at digital port n (n=1, 2)
    P/
    Outputs a 10 µs TTL pulse at B2 each n
    th
    trigger (n=1 to 255)
    Scan Commands
    SC,:
    Scans the list i..k of analog ports or digital port for n triggers. Total # of samples may not exceed 3711. (i..k=1 to 8, D)
    ES
    Ends the current scan immediately and resets the point sending counter.
    N
    Sends the next point of stored scan
    ?N
    Returns # of points scanned
    A,
    Adds n × 2.5 mV to the value of analog port 8 (must be positive) on every i
    th
    trigger (n,i=1 to 255)
    SS,:
    Scans the list i..k of analog ports or digital port for n triggers. Data is sent in a 2 byte binary format while scan is in progress.(i..k=1 to 8, D)
    X
    Sends the data of a stored scan in 2 byte binary format.
    Miscellaneous Commands
    MR
    Master Reset. Returns the SR245 to its default values.
    W
    Introduces a delay of (n × 400 µs) before sending each character over the RS-232 interface. (n=0 to 255)
    Z,